Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 28
Filter
Add more filters










Publication year range
1.
Langmuir ; 38(27): 8456-8461, 2022 Jul 12.
Article in English | MEDLINE | ID: mdl-35767433

ABSTRACT

Adhesion of a liquid droplet to a solid surface is a result of solid surface interactions with surrounding fluids, affected by its wettability and morphology. Unfortunately, the direct measurements of adhesion forces are rarely reported in the scientific literature, especially for solids with curvatures. In this study, by using a high-sensitivity microelectronic mechanical balance which vertically deposits and then pulls liquid droplets, the spreading and adhesion forces for water and ethylene glycol droplets on spherical surfaces of polyethylene terephthalate (PET) with radii of curvature from 2 to 8 mm were recorded. Results show that the surface curvature does not affect the advancing and most-stable contact angles but affects the extent of spreading and maximum adhesion forces. The solid surface curvature affects both surface tension and Laplace pressure forces at the spreading point, whereas it mainly affects the Laplace pressure force at the maximum adhesion point.

2.
Acta Biomater ; 145: 416-426, 2022 06.
Article in English | MEDLINE | ID: mdl-35367631

ABSTRACT

The metallurgical engineering of bioresorbable zinc (Zn)-based medical alloys would greatly benefit from clarification of the relationships between material properties and biological responses. Here we investigate the biocompatibility of three Zn-based silver (Ag)-containing alloys, ranging from binary to quinary alloy systems. Selected binary and quinary Zn-Ag-based alloys underwent solution treatment (ST) to increase the solubility of Ag-rich phases within the Zn bulk matrix, yielding two different microstructures (one without ST and a different one with ST) with the same elemental composition. This experimental design was intended to clarify the relationship between elemental profile/microstructure and biocompatibility for the Zn-Ag system. We found that the quinary alloy system (Zn-4Ag-0.8Cu-0.6Mn-0.15Zr) performed significantly better, in terms of histomorphometry, than any alloy system we have evaluated to date. Furthermore, when solution treated to increase strength and ductility and reduce the fraction of Ag-rich phases, the quinary alloy's biocompatibility further improved. In vitro corrosion testing and metallographic analysis of in vivo implants demonstrated a more uniform mode of corrosion for the solution treated alloy. We conclude that Zn-Ag alloys can be engineered through alloying to substantially reduce neointimal growth. The positive effect on neointimal growth can be further enhanced by dissolving the AgZn3 precipitates in the Zn matrix to improve the corrosion uniformity. These findings demonstrate that neointimal-forming cells can be regulated by elemental additions and microstructural changes in degradable Zn-based implant materials. STATEMENT OF SIGNIFICANCE: The metallurgical engineering of bioresorbable zinc (Zn)-based medical alloys would greatly benefit from clarification of the relationships between material properties and biological responses. Here, selected binary and quinary Zn-Ag-based alloys underwent solution treatment (ST) to increase the solubility of Ag-rich phases within the Zn bulk matrix, yielding two different microstructures (one without ST and a different one with ST) with the same elemental composition. We found that applying a thermal treatment restores mechanical strength and mitigates the strain rate sensitivity of Zn-Ag alloys by dissolving AgZn3 precipitates. Ag-rich nano-precipitates in Zn decrease biocompatibility, a phenomenon that can be counteracted by dissolving the AgZn3 precipitates in the bulk Zn matrix.


Subject(s)
Alloys , Zinc , Absorbable Implants , Alloys/chemistry , Alloys/pharmacology , Biocompatible Materials/chemistry , Biocompatible Materials/pharmacology , Corrosion , Materials Testing , Stents , Zinc/chemistry , Zinc/pharmacology
3.
Langmuir ; 37(7): 2532-2540, 2021 Feb 23.
Article in English | MEDLINE | ID: mdl-33555882

ABSTRACT

For applications involving droplet detachment from solid surfaces, it is vital to study the droplet characteristics (e.g., contact angle and base width) when the droplet is experiencing the maximum force that detaches the droplet (maximum adhesion state). Historically, such investigations were mainly conducted on flat two-dimensional surfaces and the characteristics on curved surfaces with the third dimension remain unknown. Thus, the generalized description of such characteristics has not been established yet. Here, by vertically pulling liquid droplets using a microbalance, we study the droplet characteristics at the maximum adhesion on curved homogeneous surfaces. Variables in this study include liquid surface tension, initial droplet base area, and the asymmetry in solid surface curvature. Results show that the contact angle is identical everywhere along the droplet perimeter on curved surfaces irrespective of the asymmetry in surface curvature. In addition, we found that the droplet base is nonaxisymmetric (not circular) at the maximum adhesion, opposing previous understanding that was formulated for flat surfaces. As a result, we propose a more generalized and quantitative description of the droplet characteristics at the maximum adhesion, derived from the component of the surface tension force acting along the droplet perimeter.

4.
Biomater Biosyst ; 4: 100027, 2021 Dec.
Article in English | MEDLINE | ID: mdl-36824572

ABSTRACT

Zinc is an essential trace element having various structural, catalytic and regulatory interactions with an estimated 3000 proteins. Zinc has drawn recent attention for its use, both as pure metal and alloyed, in arterial stents due to its biodegradability, biocompatibility, and low corrosion rates. Previous studies have demonstrated that zinc metal implants prevent the development of neointimal hyperplasia, which is a common cause of restenosis following coronary intervention. This suppression appears to be smooth muscle cell-specific, as reendothelization of the neointima is not inhibited. To better understand the basis of zinc's differential effects on rat aortic smooth muscle (RASMC) versus endothelial (RAENDO) cells, we conducted a transcriptomic analysis of both cell types following one-week continuous treatment with 5 µM or 50 µM zinc. This analysis indicated that genes whose protein products regulate mitochondrial functions, including oxidative phosphorylation and fusion/fission, are differentially affected by zinc in the two cell types. To better understand this, we performed Seahorse metabolic flux assays and quantitative imaging of mitochondrial networks in both cell types. Zinc treatment differently affected energy metabolism and mitochondrial structure/function in the two cell types. For example, both basal and maximal oxygen consumption rates were increased by zinc in RASMC but not in RAENDO. Zinc treatment increased apparent mitochondrial fusion in RASMC cells but increased mitochondrial fission in RAENDO cells. These results provide some insight into the mechanisms by which zinc treatment differently affects the two cell types and this information is important for understanding the role of zinc treatment in vascular cells and improving its use in biodegradable metal implants.

5.
Phys Rev Lett ; 125(18): 184502, 2020 Oct 30.
Article in English | MEDLINE | ID: mdl-33196248

ABSTRACT

The mobility of a fakir state droplet on a structured surface is fundamentally determined by the effective length of a microscopic contact line. However, it is largely unknown how the surface topography determines the effective contact line length. Based on the direct measurement of droplet adhesion force and the visualization of contact line, this work shows that effective contact line length is topography dependent as opposed to prior notion. On pored surfaces, contact line is not distorted, and the effective length approaches the droplet apparent perimeter regardless of pore dimensions. On pillared surfaces, the distortion of contact line is significantly dependent on the packing density of the pillar structures so that the effective length is as small as a pillar diameter on densely packed pillars and as large as a pillar perimeter on sparsely-packed pillars, while changing linearly between the two extremes.

6.
Article in English | MEDLINE | ID: mdl-32863579

ABSTRACT

The detrimental effect of natural aging on mechanical properties of zinc alloys restricts their application as bioresorbable medical implants. In this study, aging of Zn-0.05Mg alloy and the effect of 0.5 Cu and 0.1 Mn (in weight percent) addition on the microstructure and tensile properties were studied. The alloys were cold rolled, aged and annealed; aiming to investigate the effects of precipitates and grain size on the mechanical properties and their stability. TEM analysis revealed that in ultrafine-grained binary Zn-0.05Mg alloy, the natural aging occurred due to the formation of nano-sized Mg2Zn11 precipitates. After 90 days of natural aging, the yield strength and ultimate tensile strength of Zn-0.05Mg alloy increased from 197±4 MPa and 227±5 MPa to 233±8 MPa and 305±7 MPa, respectively, while the elongation was drastically reduced from 34±3% to 3±1%. This natural aging was retarded by adding the third element at either 0.1Mn or 0.5Cu quantities, which interacted with Mg in Zn solid solution and impeded the formation of Mg2Zn11 precipitates. The addition of Cu and Mn elements increased alloy's strength, ductility, and its mechanical stability at a room temperature. The measured tensile strength and elongation were 274±5 MPa and 41±1% for Zn-0.1Mn-0.05Mg and 312±2 MPa and 44±2% for Zn-0.5Cu-0.05Mg, respectively. Annealing the alloys at elevated temperatures caused increase in both grain size and dissolution of secondary phases, and both affected alloy deformation mechanisms.

8.
Mater Sci Eng C Mater Biol Appl ; 111: 110826, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32279804

ABSTRACT

Biodegradable arterial implants based on zinc have been found to suppress neointimal hyperplasia, suggesting that biodegradable materials containing zinc may be used to construct vascular implants with a reduced rate of restenosis. However, the molecular mechanism has remained unclear. In this report, we show that zinc-containing materials can be used to prevent neointimal formation when implanted into the rat aorta. Indeed, neointimal cells were significantly more TUNEL positive and alpha-actin negative at the interface of biodegradable zinc vs. biostable platinum implants, in association with greater caspase-3 activity. Although zinc stimulated extensive neointimal smooth muscle cell (SMC) death, macrophage and proinflammatory markers CD68 and iNOS were not increased in neointimal tissue relative to biostable platinum control implants. Using arterial explants, ionic zinc was confirmed to promote SMC apoptosis by activating the caspase apoptotic signaling pathway. These observations suggest that zinc-containing materials can be used to construct vascular implants such as stents with reduced neointimal hyperplasia.


Subject(s)
Absorbable Implants , Muscle, Smooth, Vascular/pathology , Myocytes, Smooth Muscle/pathology , Zinc/pharmacology , Animals , Antigens, CD/metabolism , Antigens, Differentiation, Myelomonocytic/metabolism , Caspases/metabolism , Enzyme Activation , Hyperplasia , Myocytes, Smooth Muscle/drug effects , Neointima/pathology , Nitric Oxide Synthase Type II/metabolism , Rats
9.
Langmuir ; 36(10): 2622-2628, 2020 Mar 17.
Article in English | MEDLINE | ID: mdl-32133857

ABSTRACT

Advances made in fabrication of patterned surfaces with well-defined dimensions of topographic features and their lateral dissemination drive the progress in interpretation of liquid spreading, adhesion, and retreat on engineered solid surfaces. Despite extensive studies on liquid droplet spreading and adhesion on textured surfaces in recent years, conformation of the three-phase contact line and its effect on macroscopic contact angle and droplet adhesion remain the focus of intensive debate. Here, we investigate the effect of surface topography on the adhesion force of Cassie-Baxter-state droplets on concentric ring-textured hydrophobic surfaces having rings with lateral dimensions of 5, 10, and 45 µm and separated by 5, 6, and 7 µm trenches, respectively, with fixed depth of 15 µm. Unlike mostly tested surfaces textured with straight ridges, pores, and pillars, where the droplet base contact line is anisotropic and its conformation varies along the apparent boundary, concentric rings are symmetrical and reinforce the microscopic contact line to align to a circular one that reflects the shape of the pattern. In this study, adhesion forces were calculated based on surface tension and Laplace pressure forces and were compared with the experimental forces for both water and ethylene glycol droplets having a varying contact diameter on the concentric ring-pattern at the point of maximum adhesion force. Results show that the microscopic contact line of the liquid retains its circular shape controlled by circular rings of the pattern, irrespectively of the droplet base diameter larger than 0.8 mm, and there is a good agreement between the experimental and calculated adhesion forces.

10.
Acta Biomater ; 105: 319-335, 2020 03 15.
Article in English | MEDLINE | ID: mdl-31982587

ABSTRACT

Zn-based alloys are recognized as promising bioabsorbable materials for cardiovascular stents, due to their biocompatibility and favorable degradability as compared to Mg. However, both low strength and intrinsic mechanical instability arising from a strong strain rate sensitivity and strain softening behavior make development of Zn alloys challenging for stent applications. In this study, we developed binary Zn-4.0Ag and ternary Zn-4.0Ag-xMn (where x = 0.2-0.6wt%) alloys. An experimental methodology was designed by cold working followed by a thermal treatment on extruded alloys, through which the effects of the grain size and precipitates could be thoroughly investigated. Microstructural observations revealed a significant grain refinement during wire drawing, leading to an ultrafine-grained (UFG) structure with a size of 700 nm and 200 nm for the Zn-4.0Ag and Zn-4.0Ag-0.6Mn, respectively. Mn showed a powerful grain refining effect, as it promoted the dynamic recrystallization. Furthermore, cold working resulted in dynamic precipitation of AgZn3 particles, distributing throughout the Zn matrix. Such precipitates triggered mechanical degradation through an activation of Zn/AgZn3 boundary sliding, reducing the tensile strength by 74% and 57% for Zn-4.0Ag and Zn-4.0Ag-0.6Mn, respectively. The observed precipitation softening caused a strong strain rate sensitivity in cold drawn alloys. Short-time annealing significantly mitigated the mechanical instability by reducing the AgZn3 fraction. The ternary alloy wire showed superior microstructural stability relative to its Mn-free counterpart due to the pinning effect of Mn-rich particles on the grain boundaries. Eventually, a shift of the corrosion regime from localized to more uniform was observed after the heat treatment, mainly due to the dissolution of AgZn3 precipitates. STATEMENT OF SIGNIFICANCE: Owing to its promising biodegradability, zinc has been recognized as a potential biodegradable material for stenting applications. However, Zn's poor strength alongside intrinsic mechanical instability have propelled researchers to search for Zn alloys with improved mechanical properties. Although extensive researches have been conducted to satisfy the mentioned concerns, no Zn-based alloys with stabilized mechanical properties have yet been reported. In this work, the mechanical properties and stability of the Zn-Ag-based alloys were systematically evaluated as a function of microstructural features. We found that the microstructure design in Zn alloys can be used to find an effective strategy to not only improve the strength and suppress the mechanical instability but also to minimize any damage by augmenting the corrosion uniformity.


Subject(s)
Absorbable Implants , Alloys/chemistry , Blood Vessels/pathology , Stents , Zinc/chemistry , Corrosion , Materials Testing , Solutions , Stress, Mechanical , Tensile Strength , X-Ray Diffraction
11.
ACS Appl Bio Mater ; 3(10): 6779-6789, 2020 Oct 19.
Article in English | MEDLINE | ID: mdl-33644704

ABSTRACT

Zinc (Zn) has emerged as a promising bioresorbable stent material due to its satisfactory corrosion behavior and excellent biocompatibility. However, for load bearing implant applications, alloying is required to boost its mechanical properties as pure Zn exhibits poor strength. Unfortunately, an increase in inflammation relative to pure Zn is a commonly observed side-effect of Zn alloys. Consequently, the development of a Zn-based alloy that can simultaneously feature improved mechanical properties and suppress inflammatory responses is a big challenge. Here, a bioresorbable, biocompatible Zn-Ag-based quinary alloy was comprehensively evaluated in vivo, in comparison to reference materials. The inflammatory and smooth muscle cellular response was characterized and correlated to metrics of neointimal growth. We found that implantation of the quinary alloy was associated with significantly improved inflammatory activities relative to the reference materials. Additionally, we found that inflammation, but not smooth muscle cell hyperplasia, significantly correlates to neointimal growth for Zn alloys. The results suggest that inflammation is the main driver of neointimal growth for Zn-based alloys and that the quinary Zn-Ag-Mn-Zr-Cu alloy may impart inflammation-resistance properties to arterial implants.

12.
Mater Lett ; 244: 203-206, 2019 Jun 01.
Article in English | MEDLINE | ID: mdl-31871366

ABSTRACT

In this study, the effect of grain size and precipitates on tensile properties of Zn-1.0Cu alloy were investigated. The alloy was cold rolled and annealed to manipulate the grain size and precipitation of CuZn4 particles at grain boundaries. Cold rolling resulted in an almost ultrafinegrained structure alongside precipitation of nano-sized CuZn4 particles. Strain induced precipitates triggered room temperature superplasticity through activation of Zn/CuZn4 boundary sliding, exhibiting maximum elongation of 470% at the strain rate of 1.0 × 10-4 s-1. Short-time annealing led to significantly reduced strain rate sensitivity due to the reduction of CuZn4 fraction, while the grain size remained nearly intact. This suggests that precipitates rather than grain size mainly influence the mechanical properties of Zn alloys.

13.
JOM (1989) ; 71(4): 1404-1405, 2019 Apr.
Article in English | MEDLINE | ID: mdl-31693017
14.
ACS Appl Mater Interfaces ; 11(22): 19884-19893, 2019 Jun 05.
Article in English | MEDLINE | ID: mdl-31058494

ABSTRACT

Zinc (Zn)-based biodegradable metals have been widely investigated for cardiovascular stent and orthopedic applications. However, the effect of Zn surface features on adverse biological responses has not been well established. Here, we hypothesized that a metallic zinc implant's surface oxide film character may critically influence early neointimal growth and development. Electropolishing of surfaces has become the industry standard for metallic stents, while anodization of surfaces, although not practiced on stents at present, could increase the thickness of the stable oxide film and delay early-stage implant degradation. In this study, pure zinc samples were electropolished (EP) and anodized (AD) to engineer oxide films with distinctive physical and degradation characteristics, as determined by potentiodynamic polarization, electrochemical impedance spectroscopy, and static immersion tests. The samples were then implanted within the aortic lumen of adult Sprague-Dawley rats to determine the influence of surface engineering on biocompatibility responses to Zn implants. It was found that in vitro corrosion produced a porous corrosion layer for the EP samples and a densified layer on the AD samples. The AD material was more resistant to corrosion, while localized corrosion and pitting was seen on the EP surface. Interestingly, the increased variability from localized corrosion due to the surface film character translated directly to the in vivo performance, where 100% of the AD implants but only 44% of the EP implants met the biocompatibility benchmarks. Overall, the results suggest that oxide films on degradable zinc critically affect early neointimal progression and overall success of degradable Zn materials.


Subject(s)
Biocompatible Materials/chemistry , Metals/chemistry , Zinc/chemistry , Animals , Corrosion , Materials Testing , Microscopy, Electron, Scanning , Rats , Rats, Sprague-Dawley
15.
Adv Colloid Interface Sci ; 267: 1-14, 2019 May.
Article in English | MEDLINE | ID: mdl-30861389

ABSTRACT

A contact angle observed for a liquid-solid system is not necessarily a unique value and a few different contact angles need to be carefully considered in relation to liquid spreading, adhesion and phase separation. Despite the conceptual simplicity of the contact angle and over 200 years of investigation, interpretations of experimental contact angles remain controversial, and mistakes are quite common. Here, the physics behind equilibrium contact angles are restated and their misuse in modern literature is briefly discussed. Selected advances made in the 20th century that shaped current interpretations of experimental contact angles are also critically reviewed and evaluated. Understanding of contact angles for liquids on solids has improved in the last two decades and this progress is driven by advanced imaging techniques and improved methodologies in contact angle measurements, often in tandem with direct force measurements for liquid droplets in contact with solids. In our laboratory, a microelectronic balance system is employed to measure the force of liquid droplet spontaneous spreading and the water-solid adhesion forces at different stages of droplet retraction and separation. A microbalance equipped with a camera and data acquisition software measures these forces directly, monitors droplet-surface separation including distances over which the droplet stretches, and collects optical images simultaneously. The images are used to analyze capillary and surface tension forces based on measured droplet dimensions, shapes of surfaces and values of contact angles. These force measurements have significantly furthered our fundamental understanding of advancing, receding and most stable contact angles, and their correlations with adhesion, and are summarized in this review.

16.
JOM (1989) ; 71(4): 1436-1446, 2019 Apr.
Article in English | MEDLINE | ID: mdl-33731979

ABSTRACT

Zinc alloy development and characterization for vascular stent application has been facilitated by many standardized and inexpensive methods. In contrast, overly simplistic in vitro approaches dominate the preliminary biological testing of materials. In 2012, our group introduced a metal wire implantation model in rats as a cost effective and realistic approach for the biocompatibility evaluation of degradable materials in the vascular environment. Here, we have adapted metrics routinely used for evaluating stents to quantitatively characterize the long-term progression of the neointima that forms around zinc based wire implants. Histological cross-sections were used to measure the length of neointimal protrusion from the wire into the lumen (denoted wire to lumen thickness), the base neointimal length (describing the breadth of neointimal activation), and the neointimal area. These metrics were used to provide in depth characterization details for neointimal responses to Zn-Mg and Zn-Li alloys and may be used to compare different materials.

17.
Langmuir ; 34(17): 4945-4951, 2018 05 01.
Article in English | MEDLINE | ID: mdl-29629765

ABSTRACT

Spontaneous spreading of a droplet on a solid surface is poorly understood from a macroscopic level down to a molecular level. Here, we investigate the effect of surface topography and wettability on spontaneous spreading of a water droplet. Spreading force is measured for a suspended droplet that minimizes interference of kinetic energy in the spontaneous spreading during its contact with solid surfaces of discontinuous (pillar) and continuous (pore) patterns with various shapes and dimensions. Results show that a droplet cannot spread spontaneously on pillared surfaces regardless of their shapes or dimensions because of the solid discontinuity. On the contrary, a droplet on pored surfaces can undergo spontaneous spreading whose force increases with a decrease in the advancing contact angle. Theoretical models based on both the system free energy and capillary force along the contact line validate the direct and universal dependency of the spontaneous spreading force on the advancing contact angle.

18.
Acta Biomater ; 71: 1-23, 2018 04 15.
Article in English | MEDLINE | ID: mdl-29530821

ABSTRACT

The search for biodegradable metals with mechanical properties equal or higher to those of currently used permanent biomaterials, such as stainless steels, cobalt chromium and titanium alloys, desirable in vivo degradation rate and uniform corrosion is still an open challenge. Magnesium (Mg), iron (Fe) and zinc (Zn)-based alloys have been proposed as biodegradable metals for medical applications. Over the last two decades, extensive research has been done on Mg and Fe. Fe-based alloys show appropriate mechanical properties, but their degradation rate is an order of magnitude below the benchmark value. In comparison, alongside the insufficient mechanical performance of most of its alloys, Mg degradation rate has proven to be too high in a physiological environment and corrosion is rarely uniform. During the last few years, Zn alloys have been explored by the biomedical community as potential materials for bioabsorbable vascular stents due to their tolerable corrosion rates and tunable mechanical properties. This review summarizes recent progress made in developing Zn alloys for vascular stenting application. Novel Zn alloys are discussed regarding their microstructural characteristics, mechanical properties, corrosion behavior and in vivo performance. STATEMENT OF SIGNIFICANCE: Numerous studies on magnesium and iron materials have been reported to date, in an effort to formulate bioabsorbable stents with tailorable mechanical characteristics and corrosion behavior. Crucial concerns regarding poor ductility and remarkably rapid corrosion of magnesium, and very slow degradation of iron, seem to be still not desirably fulfilled. Zinc was introduced as a potential implant material in 2013 due to its promising biodegradability and biocompatibility. Since then, extensive investigations have been made toward development of zinc alloys that meet clinical benchmarks for vascular scaffolding. This review critically surveys the zinc alloys developed since 2013 from metallurgical and biodegradation points of view. Microstructural features, mechanical, corrosion and in vivo performances of these new alloys are thoroughly reviewed and evaluated.


Subject(s)
Absorbable Implants , Alloys/pharmacokinetics , Blood Vessel Prosthesis , Zinc/pharmacokinetics , Alloys/chemistry , Animals , Humans , Stents , Zinc/chemistry
19.
Mater Sci Eng C Mater Biol Appl ; 84: 67-79, 2018 Mar 01.
Article in English | MEDLINE | ID: mdl-29519445

ABSTRACT

It is still an open challenge to find a biodegradable metallic material exhibiting sufficient mechanical properties and degradation behavior to serve as an arterial stent. In this study, Zn-Mg alloys of 0.002 (Zn-002Mg), 0.005 (Zn-005Mg) and 0.08wt% Mg (Zn-08Mg) content were cast, extruded and drawn to 0.25mm diameter, and evaluated as potential biodegradable stent materials. Structural analysis confirmed formation of Mg2Zn11 intermetallic in all three alloys with the average grain size decreasing with increasing Mg content. Tensile testing, fractography analysis and micro hardness measurements showed the best integration of strength, ductility and hardness for the Zn-08Mg alloy. Yield strength, tensile strength, and elongation to failure values of >200-300MPa, >300-400MPa, and >30% respectively, were recorded for Zn-08Mg. This metal appears to be the first formulated biodegradable material that satisfies benchmark values desirable for endovascular stenting. Unfortunately, the alloy reveals signs of age hardening and strain rate sensitivity, which need to be addressed before using this metal for stenting. The explants of Zn-08Mg alloy residing in the abdominal aorta of adult male Sprague-Dawley rats for 1.5, 3, 4.5, 6 and 11months demonstrated similar, yet slightly elevated inflammation and neointimal activation for the alloy relative to what was recently reported for pure zinc.


Subject(s)
Absorbable Implants , Alloys/chemistry , Animals , Aorta, Abdominal/pathology , Biocompatible Materials/chemistry , Biocompatible Materials/metabolism , Corrosion , Magnesium/chemistry , Rats , Rats, Sprague-Dawley , Stents , Tensile Strength , X-Ray Diffraction , Zinc/chemistry
20.
J Biomed Mater Res B Appl Biomater ; 106(1): 245-258, 2018 Jan.
Article in English | MEDLINE | ID: mdl-28130871

ABSTRACT

Special high grade zinc and wrought zinc-aluminum (Zn-Al) alloys containing up to 5.5 wt % Al were processed, characterized, and implanted in rats in search of a new family of alloys with possible applications as bioabsorbable endovascular stents. These materials retained roll-induced texture with an anisotropic distribution of the second-phase Al precipitates following hot-rolling, and changes in lattice parameters were observed with respect to Al content. Mechanical properties for the alloys fell roughly in line with strength (190-240 MPa yield strength; 220-300 MPa ultimate tensile strength) and elongation (15-30%) benchmarks, and favorable elastic ranges (0.19-0.27%) were observed. Intergranular corrosion was observed during residence of Zn-Al alloys in the murine aorta, suggesting a different corrosion mechanism than that of pure zinc. This mode of failure needs to be avoided for stent applications because the intergranular corrosion caused cracking and fragmentation of the implants, although the composition of corrosion products was roughly identical between non- and Al-containing materials. In spite of differences in corrosion mechanisms, the cross-sectional reduction of metals in murine aorta was nearly identical at 30-40% and 40-50% after 4.5 and 6 months, respectively, for pure Zn and Zn-Al alloys. Histopathological analysis and evaluation of arterial tissue compatibility around Zn-Al alloys failed to identify areas of necrosis, though both chronic and acute inflammatory indications were present. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 245-258, 2018.


Subject(s)
Alloys/chemistry , Aluminum/chemistry , Aorta , Blood Vessel Prosthesis , Materials Testing , Stents , Zinc/chemistry , Animals , Corrosion , Mice , Stress, Mechanical
SELECTION OF CITATIONS
SEARCH DETAIL
...